Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Am J Emerg Med ; 61: 111-116, 2022 11.
Artículo en Inglés | MEDLINE | ID: covidwho-2003796

RESUMEN

BACKGROUND: The nasopharyngeal swab is the gold standard collection method for COVID-19, but is invasive and painful, subsequently resulting in poor patient acceptance. This investigation explores the process of developing and validating an alternative respiratory pathogen collection device that relies on a nasopharyngeal irrigation mechanic. The primary objective was to determine if sufficient pathological sampling can be achieved by mechanism of nasopharyngeal irrigation that is proportionate to the nasopharyngeal swab method. METHODS: The study device was designed using Shapr3D modeling software and fabricated on a fused deposition modeling printer. Fifteen participants were enrolled with each receiving a saline nasopharyngeal washing using the study device. Specimen adequacy was evaluated by two real-time reverse transcriptase polymerase chain reaction (PCR) testing methods to identify the presence of the human RNase P gene. Results were evaluated quantitatively through interpretation of the PCR cycle threshold (Ct). RESULTS: All 15 specimens tested positive for the presence of RNaseP, demonstrating specimen cellularity, adequate extraction of nucleic acids, and the absence of inhibitors to amplification. The mean Ct value was 29.5 (Applied Biosystems TaqPath RT-qPCR) and 30.7 (NECoV19). All participants felt the study device irrigation procedure was faster than the nasopharyngeal swab, with none experiencing any discomfort from the irrigation mechanism. CONCLUSION: The importance of early diagnostic testing and its role in countermeasures for communicable diseases such as COVID-19 is well established in the literature. Innovation to bolster our testing infrastructure is more important now than ever. This study was successful in developing and validating an alternative nasopharyngeal respiratory pathogen collection device that utilizes fluid debridement as its core mechanic. Data from this pilot study demonstrated the study device was successful in producing high-quality specimens for PCR testing. Feedback from the study participants was also in favor of the study device when compared to the nasopharyngeal swab.


Asunto(s)
COVID-19 , Ácidos Nucleicos , Humanos , Pandemias , Proyectos Piloto , COVID-19/diagnóstico , COVID-19/epidemiología , Ribonucleasa P/genética , SARS-CoV-2 , Nasofaringe , Manejo de Especímenes/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa
2.
J Appl Microbiol ; 133(4): 2668-2677, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: covidwho-1956751

RESUMEN

AIMS: The RT-PCR is the most popular confirmatory test for SARS-CoV-2. It is sensitive, but high instrumentation cost makes it difficult for use outside routine clinical setup. This has necessitated the development of alternative methods such as CRISPR-based DETECTR method which uses lateral flow technology. Although accurate and sensitive, this method is limited by complex steps and recurrent cost of high-quality lateral flow strips. The main goal of this study was to improve the Cas12a-based SARS-CoV-2 DETECTR method and develop a portable and field-deployable system to reduce the recurring consumable cost. METHODS AND RESULTS: Specific regions of N and E genes from SARS-CoV-2 virus and human RNase P (internal control) were reverse transcribed (RT) and amplified by loop-mediated isothermal amplification (LAMP). The amplified products were detected by a Cas12a-based trans-cleavage reaction that generated a fluorescent signal which could be easily visualized by naked eye. Detection of internal control, RNase P gene was improved and optimized by redesigning RT-LAMP primers. A number of steps were reduced by combining the reagents related to the detection of Cas12a trans-cleavage reaction into a single ready-to-use mix. A portable, cost-effective battery-operated instrument, CRISPR-CUBE was developed to run the assay and visualize the outcome. The method and instrument were validated using both contrived and patient samples. CONCLUSIONS: The simplified CRISPR-based SARS-CoV-2 detection and instrument developed in this study, along with improved design for internal control detection allows for easier, more definitive viral detection requiring only reagents, consumables and the battery operable CRISPR-CUBE. SIGNIFICANCE AND IMPACT OF STUDY: Significant improvement in Cas12 method, coupled with simple visualization of end point makes the method and instrument deployable at the point-of-care (POC) for SARS-CoV-2 detection, without any recurrent cost for the lateral flow strips which is used in other POC methods.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Sistemas CRISPR-Cas , Humanos , Técnicas de Amplificación de Ácido Nucleico/métodos , Ribonucleasa P/genética , SARS-CoV-2/genética
3.
Enferm Infecc Microbiol Clin (Engl Ed) ; 40(8): 428-435, 2022 10.
Artículo en Inglés | MEDLINE | ID: covidwho-1850986

RESUMEN

INTRODUCTION: Reverse transcriptase - polymerase chain reaction (RT-PCR) is the standard technique for SARS-CoV-2 diagnosis. The World Health Organization recommends the Charité-Berlin protocol for COVID-19 diagnosis, which requires triple PCR, limiting the process capability of laboratories and delaying the results. In order to reduce these limitations, a duplex PCR is validated for the detection of the E and ribonuclease P genes. METHODS: We compared the limit of detection, sensitivity and specificity of the duplex PCR technique (E gene and Rnasa P) against the monoplex standard (E gene) in RNA samples from a SARS-CoV-2 isolate and 88 clinical specimens with previously known results. The repeatability and reproducibility of the threshold cycle values ​​(Ct) were determined in two independent laboratories of the Faculty of Medicine of the Universidad de Antioquia, using different reagents and real time instruments. RESULTS: There were no significant differences in the Ct results between both techniques (P = .84). Using the monoplex PCR of E gene as a reference, the interrater reliability analysis showed similarity between the two techniques, with a kappa coefficient of 0.89, the sensitivity and the specificity of duplex PCR were 90% and 87%, respectively. CONCLUSIONS: Duplex PCR does not affect the sensitivity and specificity reported by the Charité, Berlin protocol, being a useful tool for SARS-CoV-2 screening in clinical samples.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Prueba de COVID-19 , Humanos , Reacción en Cadena de la Polimerasa , ARN Viral/análisis , ADN Polimerasa Dirigida por ARN/genética , Reproducibilidad de los Resultados , Ribonucleasa P/genética , SARS-CoV-2/genética
4.
PLoS One ; 16(11): e0258263, 2021.
Artículo en Inglés | MEDLINE | ID: covidwho-1700786

RESUMEN

Clinical and surveillance testing for the SARS-CoV-2 virus relies overwhelmingly on RT-qPCR-based diagnostics, yet several popular assays require 2-3 separate reactions or rely on detection of a single viral target, which adds significant time, cost, and risk of false-negative results. Furthermore, multiplexed RT-qPCR tests that detect at least two SARS-CoV-2 genes in a single reaction are typically not affordable for large scale clinical surveillance or adaptable to multiple PCR machines and plate layouts. We developed a RT-qPCR assay using the Luna Probe Universal One-Step RT-qPCR master mix with publicly available primers and probes to detect SARS-CoV-2 N gene, E gene, and human RNase P (LuNER) to address these shortcomings and meet the testing demands of a university campus and the local community. This cost-effective test is compatible with BioRad or Applied Biosystems qPCR machines, in 96 and 384-well formats, with or without sample pooling, and has a detection sensitivity suitable for both clinical reporting and wastewater surveillance efforts.


Asunto(s)
COVID-19/virología , Ribonucleasa P/genética , SARS-CoV-2/genética , Aguas Residuales/virología , Cartilla de ADN/genética , Humanos , ARN Viral/genética , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Sensibilidad y Especificidad , Manejo de Especímenes/métodos , Monitoreo Epidemiológico Basado en Aguas Residuales
5.
Sci Rep ; 12(1): 2853, 2022 02 18.
Artículo en Inglés | MEDLINE | ID: covidwho-1700332

RESUMEN

Corona Virus Disease 2019 (COVID-19) is a disease caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). This pandemic has brought the world to a standstill and threatened human lives. Many methods are known to date to detect this virus. Due to their relative sensitivity, polymerase chain reaction (PCR)-based assays are the most frequently applied and considered the gold standard. However, due to the rapid mutation rate of the viral genome and the emergence of new variants, existing protocols need to be updated and improved. Designing a fast and accurate PCR-based assay is of great importance for the early detection of this virus and more efficient control of the spread of this disease. This study describes a fast, reliable, easy-to-use, and high-throughput multiplex SARS-CoV-2 RT-PCR detection method. The assay was designed to detect two viral genes (N and RdRP) and a human gene (RP) simultaneously. The performance and the sensitivity of the assay were tested in 28 SARS-CoV-2 positive samples and compared with commercial kits, which showed 100% positive percent agreement with a limit of detection (LOD) value of 1.40 and 0.81 copies/µL or 35.13 and 20.31 copies/reaction for RdRP and N genes, respectively. The current assay is found accurate, reliable, simple, sensitive, and specific. It can be used as an optimized SARS-CoV-2 diagnostic assay in hospitals, medical centers, and diagnostic laboratories as well as for research purposes.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , Proteínas de la Nucleocápside de Coronavirus/genética , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Ribonucleasa P/genética , SARS-CoV-2/aislamiento & purificación , Humanos
6.
Int J Mol Sci ; 23(4)2022 Feb 09.
Artículo en Inglés | MEDLINE | ID: covidwho-1690219

RESUMEN

The development of prophylactic agents against the SARS-CoV-2 virus is a public health priority in the search for new surrogate markers of active virus replication. Early detection markers are needed to follow disease progression and foresee patient negativization. Subgenomic RNA transcripts (with a focus on sgN) were evaluated in oro/nasopharyngeal swabs from COVID-19-affected patients with an analysis of 315 positive samples using qPCR technology. Cut-off Cq values for sgN (Cq < 33.15) and sgE (Cq < 34.06) showed correlations to high viral loads. The specific loss of sgN in home-isolated and hospitalized COVID-19-positive patients indicated negativization of patient condition, 3-7 days from the first swab, respectively. A new detection kit for sgN, gene E, gene ORF1ab, and gene RNAse P was developed recently. In addition, in vitro studies have shown that 2'-O-methyl antisense RNA (related to the sgN sequence) can impair SARS-CoV-2 N protein synthesis, viral replication, and syncytia formation in human cells (i.e., HEK-293T cells overexpressing ACE2) upon infection with VOC Alpha (B.1.1.7)-SARS-CoV-2 variant, defining the use that this procedure might have for future therapeutic actions against SARS-CoV-2.


Asunto(s)
COVID-19/virología , Proteínas de la Nucleocápside de Coronavirus/genética , SARS-CoV-2/fisiología , Replicación Viral/fisiología , Proteínas de la Nucleocápside de Coronavirus/análisis , Células Gigantes/efectos de los fármacos , Células Gigantes/virología , Células HEK293 , Humanos , Límite de Detección , Nasofaringe/virología , Fosfoproteínas/análisis , Fosfoproteínas/genética , ARN sin Sentido/farmacología , ARN Viral , Ribonucleasa P/genética , SARS-CoV-2/efectos de los fármacos , SARS-CoV-2/genética , Sensibilidad y Especificidad , Aislamiento Social , Carga Viral , Proteínas Viroporinas/genética , Replicación Viral/efectos de los fármacos
7.
Sci Rep ; 11(1): 21658, 2021 11 04.
Artículo en Inglés | MEDLINE | ID: covidwho-1503936

RESUMEN

More than one year since Coronavirus disease 2019 (COVID-19) pandemic outbreak, the gold standard technique for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) detection is still the RT-qPCR. This is a limitation to increase testing capacities, particularly at developing countries, as expensive reagents and equipment are required. We developed a two steps end point RT-PCR reaction with SARS-CoV-2 Nucleocapsid (N) gene and Ribonuclease P (RNase P) specific primers where viral amplicons were verified by agarose gel electrophoresis. We carried out a clinical performance and analytical sensitivity evaluation for this two-steps end point RT-PCR method with 242 nasopharyngeal samples using the CDC RT-qPCR protocol as a gold standard technique. With a specificity of 95.8%, a sensitivity of 95.1%, and a limit of detection of 20 viral RNA copies/uL, this two steps end point RT-PCR assay is an affordable and reliable method for SARS-CoV-2 detection. This protocol would allow to extend COVID-19 diagnosis to basic molecular biology laboratories with a potential positive impact in surveillance programs at developing countries.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/genética , COVID-19/genética , Prueba de Ácido Nucleico para COVID-19/economía , Prueba de COVID-19/métodos , Proteínas de la Nucleocápside de Coronavirus/genética , Cartilla de ADN , Electroforesis en Gel de Agar/métodos , Humanos , Laboratorios , Nasofaringe/virología , ARN Viral/genética , Ribonucleasa P/genética , Ribonucleasa P/metabolismo , SARS-CoV-2/patogenicidad , Sensibilidad y Especificidad
8.
Mol Cell Probes ; 58: 101744, 2021 08.
Artículo en Inglés | MEDLINE | ID: covidwho-1253367

RESUMEN

To increase the repertoire of PCR based laboratory developed tests (LDTs) for the detection of SARS-CoV-2, we describe a new multiplex assay (SORP), targeting the SARS-CoV-2's, Spike and ORF8 genes. The widely used human RNaseP internal control was modified to specifically co-amplify the RNaseP mRNA. The SORP triplex assay was tested on a cohort (n = 372; POS = 144/NEG = 228) of nasopharyngeal flocked swab (NPFS) specimens, previously tested for the presence of SARS-CoV-2 using a PCR assay targeting E and RdRp genes. The overall sensitivity and specificity of the SORP assay was: 99.31% (95% CI: 96.22-99.98%), 100.0% (95% CI: 98.4-100%) respectively. The SORP assay could also detect a panel of variants of concern (VOC) from the B1.1.7 (UK) and B1.351 (SA) lineage. In summary, access to a repertoire of new SARS-CoV-2 LDT's would assist diagnostic laboratories in developing strategies to overcome some of the testing issues encountered during high-throughput SARS-CoV-2 testing.


Asunto(s)
Prueba de COVID-19/métodos , COVID-19/diagnóstico , Técnicas de Laboratorio Clínico/métodos , Reacción en Cadena de la Polimerasa Multiplex/métodos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , SARS-CoV-2/genética , COVID-19/virología , Cartilla de ADN/genética , Sondas de ADN/genética , Humanos , Técnicas de Diagnóstico Molecular/métodos , Reproducibilidad de los Resultados , Ribonucleasa P/genética , SARS-CoV-2/fisiología , Sensibilidad y Especificidad , Glicoproteína de la Espiga del Coronavirus/genética , Proteínas Virales/genética
9.
J Virol Methods ; 294: 114174, 2021 08.
Artículo en Inglés | MEDLINE | ID: covidwho-1226316

RESUMEN

There is growing evidence that measurement of SARS-CoV-2 viral copy number can inform clinical and public health management of SARS-CoV-2 carriers and COVID-19 patients. Here we show that quantification of SARS-CoV-2 is feasible in a clinical setting, using a duplex RT-qPCR assay which targets both the E gene (Charité assay) and a human RNA transcript, RNase P (CDC assay) as an internal sample sufficiency control. Samples in which RNase P is not amplified indicate that sample degradation has occurred, PCR inhibitors are present, RNA extraction has failed or swabbing technique was insufficient. This important internal control reveals that 2.4 % of nasopharyngeal swabs (15/618 samples) are inadequate for SARS-CoV-2 testing which, if not identified, could result in false negative results. We show that our assay is linear across at least 7 logs and is highly reproducible, enabling the conversion of Cq values to viral copy numbers using a standard curve. Furthermore, the SARS-CoV-2 copy number was independent of the RNase P copy number indicating that the per-swab viral copy number is not dependent on sampling- further allowing comparisons between samples. The ability to quantify SARS-CoV-2 viral copy number will provide an important opportunity for viral burden-guided public health and clinical decision making.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , Prueba de Ácido Nucleico para COVID-19/normas , ARN Viral/genética , SARS-CoV-2/genética , Manejo de Especímenes/normas , COVID-19/diagnóstico , COVID-19/virología , Dosificación de Gen , Genes Esenciales , Humanos , Límite de Detección , ARN Viral/aislamiento & purificación , Estándares de Referencia , Ribonucleasa P/genética , Manejo de Especímenes/métodos , Carga Viral
10.
J Virol Methods ; 294: 114171, 2021 08.
Artículo en Inglés | MEDLINE | ID: covidwho-1226315

RESUMEN

Respiratory syncytial virus (RSV) is a common cause of acute respiratory disease worldwide, especially in young children. The World Health Organization (WHO) has initiated an RSV Surveillance Pilot program that aims to perform worldwide RSV surveillance, requiring the development of reliable and rapid molecular methods to detect and identify RSV. A duplex real-time RT-PCR assay developed for simultaneous detection of both A and B subtypes of RSV was included as part of this program. This duplex assay targeted a conserved region of the RSV polymerase gene and was validated for analytical sensitivity, specificity, reproducibility and clinical performance with a wide range of respiratory specimens. The assay was highly specific for RSV and did not react with non-RSV respiratory pathogens, including the SARS-CoV-2 virus.


Asunto(s)
Técnicas de Diagnóstico Molecular/métodos , ARN Viral/aislamiento & purificación , Virus Sincitial Respiratorio Humano/aislamiento & purificación , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Cartilla de ADN/genética , Humanos , Límite de Detección , Nasofaringe/virología , ARN Polimerasa Dependiente del ARN/genética , Reproducibilidad de los Resultados , Ribonucleasa P/genética , SARS-CoV-2/genética , Sensibilidad y Especificidad
11.
Virol Sin ; 35(6): 758-767, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: covidwho-1217478

RESUMEN

Reverse transcription-polymerase chain reaction (RT-PCR) is an essential method for specific diagnosis of SARS-CoV-2 infection. Unfortunately, false negative test results are often reported. In this study, we attempted to determine the principal causes leading to false negative results of RT-PCR detection of SARS-CoV-2 RNAs in respiratory tract specimens. Multiple sputum and throat swab specimens from 161 confirmed COVID-19 patients were tested with a commercial fluorescent RT-PCR kit targeting the ORF1ab and N regions of SARS-CoV-2 genome. The RNA level of a cellular housekeeping gene ribonuclease P/MRP subunit p30 (RPP30) in these specimens was also assessed by RT-PCR. Data for a total of 1052 samples were retrospectively re-analyzed and a strong association between positive results in SARS-CoV-2 RNA tests and high level of RPP30 RNA in respiratory tract specimens was revealed. By using the ROC-AUC analysis, we identified Ct cutoff values for RPP30 RT-PCR which predicted false negative results for SARS-CoV-2 RT-PCR with high sensitivity (95.03%-95.26%) and specificity (83.72%-98.55%) for respective combination of specimen type and amplification reaction. Using these Ct cutoff values, false negative results could be reliably identified. Therefore, the presence of cellular materials, likely infected host cells, are essential for correct SARS-CoV-2 RNA detection by RT-PCR in patient specimens. RPP30 could serve as an indicator for cellular content, or a surrogate indicator for specimen quality. In addition, our results demonstrated that false negativity accounted for a vast majority of contradicting results in SARS-CoV-2 RNA test by RT-PCR.


Asunto(s)
Prueba de COVID-19/métodos , COVID-19/diagnóstico , ARN Viral/genética , SARS-CoV-2/genética , Autoantígenos/genética , COVID-19/epidemiología , COVID-19/virología , China/epidemiología , Humanos , Resultados Negativos , Poliproteínas/genética , ARN Viral/aislamiento & purificación , Estándares de Referencia , Estudios Retrospectivos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Ribonucleasa P/genética , SARS-CoV-2/aislamiento & purificación , Sensibilidad y Especificidad , Proteínas Virales/genética
12.
J Med Virol ; 93(4): 2439-2445, 2021 04.
Artículo en Inglés | MEDLINE | ID: covidwho-996237

RESUMEN

Diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-COV-2) cases is based on the count of real-time reverse transcription-plymerase chain reaction (RT-PCR) positive people. Viral load by real-time RT-PCR has been suggested as a biomarker of the SARS-CoV-2 infection. However, the association of viral load and severity of the disease is not yet resolved. Nasopharyngeal samples from 458 patients were tested by RT-PCR for SARS-CoV-2 diagnosis. Relative quantitation was made by the comparative threshold cycle (ΔΔCt ) formula between ORF1ab viral and RNase P housekeeping genes. Absolute viral load was calculate using a reference positive control. Most prevalent clinical signs were cough (75.8%), myalgia (66.7%), and fever (48.5%). Hypertension (18.2%), neurological diseases (15.1%), and asthma and hypothyroidism (12.1%) were most frequent comorbidities. Fever, either as an exclusive symptom or combined with others, was associated with high viral loads ( 2-∆∆Ct range, 35.65-155.16; 4.25-4.89 log10 RNA copies/test]). During the first week after onset of symptoms in mild patients up to 60 years-old was detected the peak of viral load. Children under 10 years old have a high viral load (313.84; 2.50) in the first 2 days postinfection with a sharp decline thereafter. Cases between 10 and 49 years old mostly showed low and moderate viral load during the first 2 days postinfection (range, 0.03 to 17.24; -1.50 to 1.24). Patients over 60 years old have high viral load up to the second week after the onset of symptoms (range, 25.32-155.42; 1.40-2.19), indicating the longer presence of the virus in them. These findings suggest the viral load in nasopharyngeal swabs would help to monitor the SARS-CoV-2 infection in mild coronavirus disease 2019 cases.


Asunto(s)
Prueba de COVID-19/métodos , COVID-19/virología , Nasofaringe/virología , ARN Viral/aislamiento & purificación , SARS-CoV-2/genética , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , COVID-19/diagnóstico , Niño , Preescolar , Pruebas Diagnósticas de Rutina , Femenino , Humanos , Lactante , Masculino , Persona de Mediana Edad , Poliproteínas/genética , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Ribonucleasa P/genética , SARS-CoV-2/aislamiento & purificación , Carga Viral , Proteínas Virales/genética , Adulto Joven
13.
Eur J Clin Microbiol Infect Dis ; 40(4): 807-813, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: covidwho-891909

RESUMEN

The purpose of this study is to develop a one-step droplet digital RT-PCR (RT-ddPCR) multiplex assay that allows for sensitive quantification of SARS-CoV-2 RNA with respect to human-derived RNA and could be used for screening and monitoring of Covid-19 patients. A one-step RT-ddPCR multiplex assay was developed for simultaneous detection of SARS-CoV-2 E, RdRp and N viral RNA, and human Rpp30 DNA and GUSB mRNA, for internal nucleic acid (NA) extraction and RT-PCR control. Dilution series of viral RNA transcripts were prepared in water and total NA extract of Covid-19-negative patients. As reference assay, an E-GUSB duplex RT-PCR was used. GUSB mRNA detection was used to set validity criteria to assure viral RNA and RT-PCR assay quality and to enable quantification of SARS-CoV-2 RNA. In a background of at least 100 GUSB mRNA copies, 5 copies of viral RNA are reliably detectable and 10 copies viral RNA copies are reliably quantifiable. It was found that assay sensitivity of the RT-ddPCR was not affected by the total NA background while assay sensitivity of the gold standard RT-PCR assay is drastically decreased when SARS-CoV-2 copies were detected in a background of total NA extract compared with water. The present study describes a robust and sensitive one-step ddRT-PCR multiplex assay for reliable quantification of SARS-CoV-2 RNA. By determining the fractional abundance of viral RNA with respect to a human housekeeping gene, viral loads from different samples can be compared, what could be used to investigate the infectiveness and to monitor Covid-19 patients.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , ADN/análisis , Reacción en Cadena de la Polimerasa Multiplex/métodos , ARN Mensajero/análisis , ARN Viral/análisis , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Autoantígenos/genética , Proteínas de la Envoltura de Coronavirus/genética , Proteínas de la Nucleocápside de Coronavirus/genética , ARN Polimerasa Dependiente de ARN de Coronavirus/genética , Genes Esenciales , Glucuronidasa/genética , Humanos , Fosfoproteínas/genética , Reacción en Cadena en Tiempo Real de la Polimerasa , Ribonucleasa P/genética , SARS-CoV-2 , Sensibilidad y Especificidad
14.
Clin Chem Lab Med ; 58(9): 1579-1586, 2020 08 27.
Artículo en Inglés | MEDLINE | ID: covidwho-612047

RESUMEN

Objectives: The direct identification of SARS-CoV-2 RNA in nasopharyngeal swabs is recommended for diagnosing the novel COVID-19 disease. Pre-analytical determinants, such as sampling procedures, time and temperature storage conditions, might impact on the end result. Our aim was to evaluate the effects of sampling procedures, time and temperature of the primary nasopharyngeal swabs storage on real-time reverse-transcription polymerase chain reaction (rRT-PCR) results. Methods: Each nasopharyngeal swab obtained from 10 hospitalized patients for COVID-19 was subdivided in 15 aliquots: five were kept at room temperature; five were refrigerated (+4 °C); five were immediately mixed with the extraction buffer and refrigerated at +4 °C. Every day and for 5 days, one aliquot per condition was analyzed (rRT-PCR) for SARS-CoV-2 gene E and RNaseP and threshold cycles (Ct) compared. To evaluate manual sampling, 70 nasopharyngeal swabs were sampled twice by two different operators and analyzed separately one from the other. Results: A total of 6/10 swabs were SARS-CoV-2 positive. No significant time or storage-dependent variations were observed in SARS-CoV-2 Ct. Re-sampling of swabs with SARS-CoV-2 Ct lower than 33 resulted in highly reproducible results (CV=2.9%), while a high variability was observed when Ct values were higher than 33 (CV=10.3%). Conclusions: This study demonstrates that time and temperature of nasopharyngeal swabs storage do not significantly impact on results reproducibility. However, swabs sampling is a critical step, and especially in case of low viral load, might be a potential source of diagnostic errors.


Asunto(s)
Betacoronavirus/química , Nasofaringe/virología , ARN Viral/análisis , Manejo de Especímenes/métodos , Anciano , Anciano de 80 o más Años , COVID-19 , Prueba de COVID-19 , Técnicas de Laboratorio Clínico , Proteínas de la Envoltura de Coronavirus , Infecciones por Coronavirus/diagnóstico , Pruebas Diagnósticas de Rutina , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pandemias , Neumonía Viral/diagnóstico , Reproducibilidad de los Resultados , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Ribonucleasa P/genética , SARS-CoV-2 , Temperatura , Factores de Tiempo , Proteínas del Envoltorio Viral/genética
15.
Int J Mol Sci ; 21(9)2020 May 01.
Artículo en Inglés | MEDLINE | ID: covidwho-155285

RESUMEN

In this work, hybridization chain reactions (HCRs) toward Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) nucleocapsid phosphoproteins gene loci and human RNase P are proposed to provide an isothermal amplification screening tool. The proposed chain reactions target the complementary DNA (cDNA) of SARS-CoV-2, with loci corresponding to gold-standard polymerase chain reaction (PCR) loci. Four hybridization chain reaction reactions are demonstrated herein, targeting N1/N2/N3 loci and human RNase P. The design of the hybridization chain reaction, herein, is assisted with an algorithm. The algorithm helps to search target sequences with low local secondary structure and high hybridization efficiency. The loop domain of the fuel hairpin molecule H1 and H2, which are the tunable segments in such reactions, are used as an optimization parameter to improve the hybridization efficiency of the chain reaction. The algorithm-derived HCR reactions were validated with gel electrophoresis. All proposed reactions exhibit a hybridization complex with a molecular mass >1.5k base pairs, which is clear evidence of chain reaction. The hybridization efficiency trend revealed by gel electrophoresis corresponds nicely to the simulated data from the algorithm. The HCR reactions and the corresponding algorithm serve as a basis to further SARS-CoV-2 sensing applications and facilitate better screening strategies for the prevention of on-going pandemics.


Asunto(s)
Betacoronavirus/genética , Betacoronavirus/aislamiento & purificación , Infecciones por Coronavirus/diagnóstico , Tamizaje Masivo/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , Neumonía Viral/diagnóstico , COVID-19 , Simulación por Computador , Infecciones por Coronavirus/virología , ADN Complementario/genética , Humanos , Pandemias , Neumonía Viral/virología , Reacción en Cadena de la Polimerasa/métodos , Ribonucleasa P/genética , SARS-CoV-2
16.
Rev Med Virol ; 30(3): e2106, 2020 05.
Artículo en Inglés | MEDLINE | ID: covidwho-71880

RESUMEN

Emerging and reemerging infectious diseases are global public concerns. With the outbreak of unknown pneumonia in Wuhan, China in December 2019, a new coronavirus, SARS-CoV-2 has been attracting tremendous attention. Rapid and accurate laboratory testing of SARS-CoV-2 is essential for early discovery, early reporting, early quarantine, early treatment, and cutting off epidemic transmission. The genome structure, transmission, and pathogenesis of SARS-CoV-2 are basically similar to SARS-CoV and MERS-CoV, the other two beta-CoVs of medical importance. During the SARS-CoV and MERS-CoV epidemics, a variety of molecular and serological diagnostic assays were established and should be referred to for SARS-CoV-2. In this review, by summarizing the articles and guidelines about specimen collection, nucleic acid tests (NAT) and serological tests for SARS-CoV, MERS-CoV, and SARS-CoV-2, several suggestions are put forward to improve the laboratory testing of SARS-CoV-2. In summary, for NAT: collecting stool and blood samples at later periods of illness to improve the positive rate if lower respiratory tract specimens are unavailable; increasing template volume to raise the sensitivity of detection; putting samples in reagents containing guanidine salt to inactivate virus as well as protect RNA; setting proper positive, negative and inhibition controls to ensure high-quality results; simultaneously amplifying human RNase P gene to avoid false-negative results. For antibody test, diverse assays targeting different antigens, and collecting paired samples are needed.


Asunto(s)
Técnicas de Laboratorio Clínico/métodos , Enfermedades Transmisibles Emergentes/virología , Anticuerpos Antivirales/aislamiento & purificación , Betacoronavirus/genética , Betacoronavirus/aislamiento & purificación , Prueba de COVID-19 , Enfermedades Transmisibles Emergentes/diagnóstico , Infecciones por Coronavirus/diagnóstico , Cartilla de ADN , Humanos , Coronavirus del Síndrome Respiratorio de Oriente Medio/genética , Coronavirus del Síndrome Respiratorio de Oriente Medio/aislamiento & purificación , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Ribonucleasa P/genética , Ribonucleasa P/aislamiento & purificación , Coronavirus Relacionado al Síndrome Respiratorio Agudo Severo/genética , Coronavirus Relacionado al Síndrome Respiratorio Agudo Severo/aislamiento & purificación , SARS-CoV-2 , Pruebas Serológicas/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA